In Physical Design mainly Six inputs
are present
1.
Logical
libraries --> format is .lib
--->given by Vendors
2.
physical libraries
-->format is .lef --->given by vendors
3.
Technology
file -->format is
.tf --->given by fabrication peoples
4.
TLU+
file
-->format is .TLUP-->given by fabrication people
5.
Netlist
--->format is .v -->given by
Synthesis People
6.
Synthesis Design Constraints
-->format is .SDC -->given by Synthesis People
LOGICAL LIBRARIES
Logical libraries :format is .lib
1.
Timing information of Standard
cells,Soft macros,Hard macros.
2.
functionality information of
Standard cells,Soft macros.
3.
And design rules like max
transition ,max capacitance, max fanout.
4.
In timing information Cell delays
,Setup,Hold time are present.
5.
Cell delay is Function of input
transition and output load.
6.
Cell delay is calculated based on
lookup tables.
7.
Cell delays are calculated by using
linear delay models,Non linear delay models,CCS models.
8.
functionality is used for
Optimization Purpose.
9.
And also Contain Power information.
10. And
contains Leakage power for Default cell,Leakage Power Density for cell,Default
Input voltage , Out put voltage.
And PVT contains ------->Cell leakage Power
-------->Internal Power
--------->Rise Transition
And it contains A view(sub directory) i.e. LM(Logical Model view)view.
It contains logical libraries.
-------->Internal Power
--------->Rise Transition
And it contains A view(sub directory) i.e. LM(Logical Model view)view.
It contains logical libraries.
PHYSICAL LIBRARIES
Physical libraries: format is .lef:
1.
physical information of std
cells,macros,pads.
2.
Pin information.
3.
Define unit tile placement.
4.
Minimum Width of Resolution.
5.
Hight of the placement Rows .
6.
Preferred routing Directions.
7.
Pitch of the routing tracks.
8.
Antena Rules.
9.
Routing Blockages
In physical info height,area,width are present.
and also it contains two views
1)Cell View:
In this all layout information is present,it is used at the time of tapeout
2)FRAM view:
Fram view is abstract view, it is used at the Place & Route
and also it contains two views
1)Cell View:
In this all layout information is present,it is used at the time of tapeout
2)FRAM view:
Fram view is abstract view, it is used at the Place & Route
TECHNOLOGY FILE
Technology file: format is .tf:
1.
It contains Name,Number conventions
of layer and via
2.
It contains Physical,electrical
characteristics of layer and via
3.
In Physical characteristics Min
width,area,height are present.
4.
In Electrical characteristics
Current Density is present.
5.
Units and Precisions of layer and
via .
6.
Colors and pattern of layer and via
.
7.
Physical Design rules of layer and
via
8.
In Physical Design rules Wire to
Wire Spacing,Min Width between Layer and via are present.
TLU PLUS
TLU+ files: format is .TLUP:
1.
R,C parasitics of metal per unit
length.
2.
These(R,C parasitics) are used for
calculating Net Delays.
3.
If TLU+ files are not given then
these are getting from .ITF file.
4.
For Loading TLU+ files we have load
three files .
5.
Those are Max Tlu+,Min TLU+,MAP
file.
6.
MAP file maps the .ITF file and .tf
file of the layer and via names.
NETLIST
Netlist:
Format is .V
It contains Logical connectivity Of all Cell(Std cells,Macros).
It contain List of nets.
In the design for Knowing connectivity by using Fly lines.
It contains Logical connectivity Of all Cell(Std cells,Macros).
It contain List of nets.
In the design for Knowing connectivity by using Fly lines.
SDC
SDC :Format is .SDC :
These Constraints are timing Constraints .
These Constraints used for to meet timing requirements.
Constraints are
These Constraints are timing Constraints .
These Constraints used for to meet timing requirements.
Constraints are
1.
CLOCK DEFINITIONS:Create Clock
Period.
2.
Generated Clock Definitions
3.
Input Delay
4.
Output Delay
5.
I/O delay
6.
Max delay
7.
Min Delay
8.
--------------->Exceptions<-------------------------
9.
Multi cycle path
10. False
path
11. Half
cycle path
12. Disable
timing arcs
13. Case
Analysis
Multi cycle path, False path are Exceptions.